Coaxial cable transmits data by guiding a radio-frequency electromagnetic wave through the space between a central copper conductor and a surrounding shield, rather than through the copper itself. An oscillating voltage at the transmitter launches that wave, the dielectric keeps the conductors at a fixed spacing, and the shield confines the field so the signal arrives at the receiver with little loss or leakage.
That one-sentence answer hides a lot of engineering. Coax is a transmission line, not a wire in the ordinary sense, and almost everything that makes it work follows from geometry, dielectric chemistry, and frequency. The sections below work through the mechanism, the numbers that constrain it, and the places where common explanations go wrong.
The waveguide between two conductors
Electric current does flow in the copper, but the energy that reaches your modem or television travels as a field in the insulating gap. The inner conductor carries current on its outer surface and the shield carries an equal return current on its inner surface. The two currents are always opposite in direction and equal in magnitude, and their magnetic fields cancel almost completely outside the cable. That cancellation is the shielding.
The dielectric does more than hold the parts apart. It sets the speed at which the wave propagates, and it damps losses that would otherwise climb sharply with frequency. A solid polyethylene dielectric slows the wave to roughly 66 percent of the speed of light in vacuum. Foamed dielectrics, which are mostly gas by volume, reach 80 to 88 percent. Air-spaced hardline approaches 93 percent.
Characteristic impedance follows from the ratio of conductor diameters and the dielectric constant. The standard 75-ohm value used in video and broadband comes from a geometry that minimizes loss per unit length. The 50-ohm value used in radio test equipment and lab gear comes from a geometry that maximizes power handling. The familiar 75-ohm figure is a loss optimization, not an arbitrary standard, and the 50/75 split is one of the clearest signs that impedance is a design choice.
One consequence surprises people. If a cable's impedance matches the source and the load, the voltage and current vary smoothly along its length. If it does not, part of the wave reflects at the mismatch and travels backward, and the forward and reflected waves interfere to create standing waves. Those standing waves raise voltage at some points far above what the transmitter delivers, and they waste power. Matching is not cosmetic.
Quantified behavior: attenuation, bandwidth, and reach
Signal loss in coax is measured in decibels per 100 feet at a stated frequency, and it rises with frequency. A typical RG-6 drop cable built for satellite and cable TV loses roughly 1 to 2 dB per 100 feet at the low VHF band, climbing to around 5 to 6 dB per 100 feet near 1 GHz and higher still at 2 GHz. Larger cable with a foam dielectric and a bigger shield does better at the same frequency, which is why trunk runs use thick hardline and the last run into a house uses thin RG-6.
Decibels compound, and the arithmetic is worth internalizing. Every 3 dB of loss halves the power that survives. A 10 dB loss leaves one-tenth. A run that loses 20 dB has thrown away 99 percent of the launched power, and no amplifier recovers it, because an amplifier boosts signal and noise together while adding noise of its own.
Frequency division is what lets one cable carry many services at once. Legacy cable television placed 6 MHz channels side by side, with the lowest video carriers around 55 MHz and the band extending upward. Modern hybrid fiber-coax networks push the usable spectrum to 1 GHz or beyond and reserve some of it for upstream traffic from the subscriber. Each channel occupies its own slice, and the receiver filters out everything else. That is frequency multiplexing, and it is the reason a single coax drop can serve television, internet, and voice simultaneously.
Attenuation is not the only limit. The shield's effectiveness falls as frequency rises, and above roughly 2 to 3 GHz, depending on construction, a conventional braided shield leaks enough to cause problems. A second mechanism, radiation from the cable itself, becomes significant when the cable is long relative to the wavelength of the signal. Wavelength shrinks as frequency climbs, which is why very high frequencies demand better connectors and tighter shielding.
Timeline: how a bit becomes a wave
| Stage | What happens | Order of magnitude |
|---|---|---|
| Modulation | Digital bits map onto a carrier's amplitude and phase | Carrier at tens to hundreds of MHz, symbol rate in megasymbols per second |
| Launch | Transmitter drives the cable input | Voltage swings of a few volts peak-to-peak |
| Propagation | Wave travels at 66–88% of light speed | Roughly 1.2–1.5 ns per foot of cable |
| Attenuation | Resistive and dielectric losses shrink the wave | 1–6 dB per 100 ft depending on frequency |
| Reflection | Mismatches send part of the wave backward | Return loss of 10–20 dB typical for decent terminations |
| Reception | Equalizer and demodulator recover symbols | Adaptive equalization compensates for cable response |
| Error control | Forward error correction repairs residual errors | Corrects a fraction of corrupted symbols |
The propagation delay is worth a second look. At roughly 1.5 nanoseconds per foot, a 100-foot run adds about 150 ns of latency. That is small compared with network round-trip times, but it matters for timing-sensitive systems and for systems that try to synchronize clocks over the cable. The equalizer's job is to undo the frequency-dependent loss and delay so that the receiver sees a clean symbol at the sampling instant.
Edge cases and failure modes
A bent or kinked cable changes its geometry locally, which changes the local impedance and creates a reflection. A damaged shield lets outside radio energy in, and the cable becomes an antenna for interference. Water in the dielectric raises loss dramatically, because water has a high dielectric constant and absorbs energy; a single pinhole in the jacket can quietly ruin a drop over a season.
Return loss quantifies how well a termination matches. A poor connector might give 10 dB return loss, meaning about 10 percent of the incoming power reflects back. A good connector gives 20 dB or better, around 1 percent. That difference matters because reflections combine with the forward wave and degrade the signal-to-noise ratio the receiver needs.
A less obvious failure is the shield's transfer impedance. Braided shields are not perfect. The braid carries return current on its inner surface, but the weave has gaps, and at high frequencies the current can couple through those gaps. Foil-laminate shields and triple-shield constructions reduce this leakage, and connectors that do not bond the shield well become the weakest link in the chain. The connector, not the cable, is usually where shielding fails.
Counterintuitive details and professional caveats
Two things are counterintuitive enough to state plainly. First, the signal does not travel in the copper. It travels in the dielectric gap, and the copper's job is to guide and confine it. That is why dielectric quality matters more than people expect. Second, the center conductor carries current only on its surface at high frequency, a phenomenon called skin effect, and the skin depth shrinks as frequency rises. At 1 GHz in copper the skin depth is a few micrometers. Plating the center conductor with a low-resistivity metal is therefore more useful than making the conductor thicker, because the current only sees the surface anyway.
The professional caveat concerns what "impedance match" means in practice. Transmitters and receivers are designed for a nominal impedance, and cables are specified at a nominal impedance, but the match is never perfect across all frequencies. Broadband terminations use resistive and reactive networks to approximate a match over the band, and the quality of that approximation shows up as return loss. A cable that is perfect at 100 MHz may be poor at 1 GHz, and a specification sheet's "75 ohms" describes a nominal character, not a constant.
A third detail matters at high frequencies: connector quality. The transition from cable to connector is a discontinuity, and the higher the frequency, the more that discontinuity reflects. A cheap connector on a good cable can dominate the total loss and reflection of a link. This is why field technicians are trained to inspect and torque connectors rather than to trust the cable alone.
Common misconceptions
The persistent idea that coax is "just a shielded wire" misses the point. A shielded wire carrying a low-frequency signal behaves nothing like a transmission line; a coax carrying a gigabit-class signal is a distributed system in which length, termination, and dielectric all shape the result. The distinction explains why audio and low-speed control signals tolerate sloppy cabling that would ruin a broadband link.
A second misconception is that thicker cable is always better. Thicker cable does lower attenuation, but it also becomes stiff, hard to bend, and expensive. The right choice is the one that meets the loss budget at the highest frequency of interest, not the largest diameter available. A third is that amplifiers fix a bad cable. They do not. An amplifier placed after a lossy run raises the noise floor along with the signal, and the recovered signal-to-noise ratio is worse than it would have been with a proper cable.
A kinked or crushed cable creates a local impedance change and a reflection. A loose connector raises return loss and can admit interference. Moisture in the dielectric raises attenuation sharply and is often irreversible. A shield that is not bonded at both ends of a connector path leaks, regardless of braid quality. A cable rated for a lower frequency will still pass a signal, but its loss and reflection performance may be outside specification at the higher band.
Practical actions and thresholds
Start with a loss budget. Add up the attenuation of the cable at the highest frequency in use, then add the insertion loss of splitters and connectors. If the total approaches the receiver's tolerance, shorten the run or use a lower-loss cable. A useful rule of thumb is to keep a single drop run well under 150 feet for typical RG-6 residential service, and to use larger cable for longer runs or higher frequencies.
Choose cable by construction, not by marketing. Foam-dielectric RG-6 with a foil-plus-braid shield is the residential default. Tight-buffered or flooded cable is appropriate where moisture is likely. For runs approaching 1 GHz and beyond, prefer cable with specified loss at that frequency rather than a generic rating.
Terminate every unused port. An open port reflects the signal back and degrades the match for everything sharing the splitter. Use a terminator rated for the band in use, typically 75 ohms.
Inspect connectors before trusting a measurement. A swept return-loss measurement through a bad connector will report the connector, not the cable. Field measurements of return loss should be made with a calibrated instrument and a known-good reference termination.
If a link underperforms, test in this order: connector seating and condition, cable continuity, return loss, then attenuation. That order catches the most common faults first, and it avoids the temptation to replace a cable that only needed a connector seated.
Limits of what coaxial can do
Coax has real ceilings. Its attenuation rises steadily with frequency, so the practical upper band is set by how much loss the receiver can tolerate. The shield becomes less effective at very high frequencies, which limits both leakage and ingress performance. The cable's physical size sets a floor on bending radius and a ceiling on how much cable a technician can reasonably install.
Distance and bandwidth trade against each other. A short run supports a very wide band. A long run supports less, and the network design has to account for the worst-case drop rather than the average one. That is why modern hybrid fiber-coax systems push fiber closer to the subscriber and reserve coax for the last few hundred feet, where its cost and installability still win.
The honest summary of the mechanism is this: coax works because a carefully chosen pair of conductors and a dielectric guide an electromagnetic wave with predictable loss and predictable speed, and because frequency division lets many signals share that guide without colliding. Everything else, from connector quality to moisture control to termination practice, exists to keep the wave clean from one end to the other.